<LOGO>
FM Transmitter Measurement Report
Created: 2026-09-01 07-19-33
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
94.70 MHz 5/5, 49 dBuV SANDELS
Pilot RDS Phase Difference
4.9 kHz 5.3 kHz No phase relation found.
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 1,0 kHz
MIN Hold Max. Samples at Total Samples % above 76,0 kHz
11 kHz 15 kHz 14275 3,7548
Modulation Power
Limit Measuring Tolerance
12,0 dBr 0,2 dBr
MIN AVE MAX % above 12,2 dBr
2,6 dBr 4,40 dBr 6,4 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
"SANDELS " 61F1 9 (Varied) 1 0 1 13 --:--
RT
-
AF EON
94.7, 103.8 MHz -
FM Scope Max at: 15 kHz MIN: 11 kHz % above 76 kHz: 3,7548 Acquired: 2026.09.01 7.18.30 Total samples: 14275 Equivalent time: 0:11:53 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 500 1000
FM Scope MAX: 6,4 dBr MIN: 2,6 dBr AVE: 4,40 dBr % above 12,2 dBr: 0,0 Last value: 4,8 dBr (2026.09.01 7.18.29) 07.04 07.06 07.08 07.10 07.12 07.14 07.16 07.18 0 2 4 6 Pm [dBr]